8. terminal strip 3t connections (optional) – Hobart Welding Products CONTRACTOR 40D OM-474 Manuel d'utilisation

Page 21

Advertising
background image

OM-474 Page 17

4-7.

Remote 14 Receptacle RC3 Information (Optional, See Section 4-8)

Socket*

Socket Information

A

24 volts ac. Protected by circuit
breaker CB4.

B

Contact closure to A completes 24
volts ac contactor control circuit.

A

J

I

115 volts ac. Protected by circuit
breaker CB3.

B

K

I

C

L

N

H

J

Contact closure to I completes 115
volts ac contactor control circuit.

D

M

G

E

F

G

Circuit common for 24 and 115 volts ac
circuits.

C

0 to +10 volts dc output to remote
control.

D

Remote control circuit common.

A/V

E

0 to +10 volts dc input command signal
from remote control.

Ref. ST-154 862-A

K

Chassis common.

*The remaining sockets are not used.

4-8.

Terminal Strip 3T Connections (Optional)

Ref. ST-139 670-B / ST-185 316 / Ref. ST-191 898

Y

Stop engine.

If remote control plug does not fit in
receptacle RC3, wire cord directly
to terminal strip 3T.

Y

Do not connect to Remote 14
receptacle RC3 and terminal
strip 3T at the same time. Use
only one remote control
method.

Open right side door.

1

Cover

2

Terminal Strip 3T

Connect leads to 3T using terminal
information shown in Section 4-7.

Reinstall cover. Close door.

1

2

Tools Needed:

Advertising