3. unit overload, 4. changing drive roll and wire inlet guide, 5. aligning drive rolls and wire guide – Hobart Welding Products M-25 GUN Manuel d'utilisation

Page 25: 6. replacing gun contact tip

Advertising
background image

OM-194 430 Page 21

4-3.

Unit Overload

If unit is used beyond capacity (excessive wire feed, shorted output, etc.), wire feeds but is not energized. Release gun
trigger to reset this condition.

4-4.

Changing Drive Roll And Wire Inlet Guide

ST-150 227-C

Tools Needed:

1

3

2

4

5

1

Securing Screw

2

Inlet Wire Guide

Loosen screw. Slide tip as close to
drive rolls as possible without touch-
ing. Tighten screw.

3

Anti-Wear Guide

Install guide as shown.

4

Drive Roll

Install correct drive roll for wire size
and type.

5

Drive Roll Securing Nut

Turn nut one click to secure drive
roll.

5/64 in

7/16 in

4-5.

Aligning Drive Rolls And Wire Guide

Y

Turn Off power.

View is from top of drive rolls look-
ing down with pressure assembly
open.

1

Drive Roll Securing Nut

2

Drive Roll

3

Wire Guide

4

Welding Wire

5

Drive Gear

Insert screwdriver, and turn screw
in or out until drive roll groove lines
up with wire guide.

Close pressure roll assembly.

Close door.

Ref. ST-800 412-A

Correct

Incorrect

4

3

2

1

5

Tools Needed:

4-6.

Replacing Gun Contact Tip

Ref. 800 797-C

Y

Turn Off power before
replacing contact tip.

1

Nozzle

2

Contact Tip

Cut off welding wire at contact tip.
Remove nozzle.

Remove contact tip and install new
contact tip. Reinstall nozzle.

1

2

Tools Needed:

Advertising
Ce manuel est liée aux produits suivants: