1. routine maintenance, 2. circuit breaker cb1 – Hobart Welding Products M-25 GUN Manuel d'utilisation

Page 24

Advertising
background image

OM-194 430 Page 20

SECTION 4 – MAINTENANCE AND TROUBLESHOOTING

4-1.

Routine Maintenance

Y

Disconnect power before maintaining.

3 Months

Replace unreadable labels.

Repair or replace
cracked weld cable.

Clean and tighten weld terminals.

6 Months

Blow out or vacuum
inside. During heavy
service, clean monthly.

OR

Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.

4-2.

Circuit Breaker CB1

Ref. ST-801 789 / Ref. 800 797-C

1

Circuit Breaker CB1

If CB1 opens, wire feeding stops.

2

Welding Gun

Check gun liner for blockage or
kinks.

3

Wire Drive Assembly

Check for jammed wire, binding
drive gear or misaligned drive rolls.

Allow cooling period and reset
breaker. Close door.

1

2

3

Advertising