Modification to reduce ozone odor, Caution, Replacing ionizer wires – Honeywell F300 Manuel d'utilisation

Page 14

Advertising
background image

F300 ELECTRONIC AIR CLEANER

68-0240EF-5

14

Replacing Ionizer Wires

Broken or bent ionizer wires can cause an electrical short to

ground, often resulting in visible arcing or sparking. Do not use

cells until broken wires are removed. Cells can be used

temporarily with one wire missing, but replace the wire as soon

as possible.

Replacement wires are supplied cut to length with eyelets on

both ends for easy installation. See Parts and Accessories Not

Illustrated section. To install:

1. Hook the eyelet on one end of the wire over the spring

connector on one end of the cell. See Fig. 15. Be careful

to avoid damaging spring connectors or other parts of

the cells.

2. Hold the opposite eyelet with a needle nose pliers and

stretch the wire the length of the cell. Depress the

opposite spring connector and hook the eyelet over it.

3. Check the cell for short circuits using an ohmmeter; see

Fig. 16. Check the resistance between the frame of the

cell and both the ionizer and the collector contacts. In

each case, the resistance should be infinite.

Fig. 15. Replacing an ionizer wire.

Fig. 16. Use ohmmeter to check electronic cells for short

circuits.

Modification to Reduce Ozone Odor

CAUTION

Electric Shock Hazard.

Can cause personal injury.

Always disconnect power and open access door before

opening power supply cover.

The electronic air cleaner generates a small amount of ozone

in normal operation. During the first week or two of operation,

the amount may be higher because of sharp edges on some of

the new high voltage metal parts. Normal use quickly dulls

these edges.

The average person can detect the odor of ozone in

concentrations as low as 0.003 to 0.010 parts per million

(ppm). The electronic air cleaner contributes 0.005 to 0.010

ppm of ozone to the indoor air. The U.S. Food and Drug

Administration and Health and Welfare Canada recommend

that indoor ozone concentration should not exceed 0.050 ppm.

As a comparison, the outdoor ozone level in major cities is

sometimes as high 0.100 ppm.

However, if desired, the ozone generated by the air cleaner

can be reduced in one of two ways:

1. Install an activated carbon filter downstream from the air

cleaner. Make sure particles from the air filter cannot fall

into the air cleaner.

M1540B

IONIZER

WIRE

IONIZER

WIRE

NEEDLENOSE

PLIERS

SPRING

CONNECTORS

PRESS

DOWN

EYELETS

REPLACING AN IONIZER WIRE.

TWO EYELETS HOLD IONIZER WIRE TO CELL.

1

1

COLLECTOR

TERMINAL

COLLECTOR

TERMINAL

IONIZER

TERMINAL

M6155