Operation, Checkout, Inspect the installation – Honeywell F300 Manuel d'utilisation

Page 11

Advertising
background image

F300 ELECTRONIC AIR CLEANER

11

68-0240EF-5

1. Open access door.

2. Remove and retain the two screws from the front of the

power box and the two screws from the sides of the

power box. See Fig. 11.

3. In the power box, remove and retain two wire nuts that

connect the line cord leads to the power box wiring.

4. Remove the power cord green lead from the green

grounding screw on the wiring compartment barrier.

5. Remove the power cord and the strain relief.

6. Install the plug (provided with the literature pack) in the

hole left by the power cord.

7. Attach conduit through a power box side knockout.

8. Wire the air cleaner directly to line voltage using wire

nuts. See Fig. 12. Secure ground connection to the

green ground screw on the wiring compartment barrier.

9. Replace power supply cover and access door.

Fig. 11. Removing cover from power box.

Fig. 12. Conduit connection for electronic air cleaner.

OPERATION

Large particles (lint, hair) are caught by the prefilter. As the

dirty air passes through the intense high voltage electric field

surrounding the ionizer wires, all particles are given an

electrical charge.

The air then moves through the collector part of the cell where

alternate parallel plates are charged positively and negatively,

creating a uniform electrostatic field. The charged particles are

attracted to and collect on the plates that have the opposite

electrical charge.

The air then passes through media postfilters, removing

additional particles from the air stream. The air leaving the air

cleaner has fewer particles. Each time the air circulates

through the electronic air cleaner, more particles are removed.

CHECKOUT

Inspect the Installation

Make sure:

• Turning vanes and transitions, as needed, are correctly

installed.

• Sheet metal joints between air cleaner and furnace are

sealed.

• All sheet metal connections are complete.

• Original furnace filter has been removed and the blower

compartment cleaned.

• If atomizing humidifier is installed upstream from the air

cleaner, a disposable furnace filter is installed between the

humidifier and the air cleaner.

• Outside air, if used, is mixed with return air or heated, as

necessary, before it can reach the air cleaner.

• Airflow arrows on the electronic cell point downstream.

• Metal mesh prefilter is on the upstream side and media

postfilter is on downstream side of the cell.

• Cell handle faces outward.

• Electronic cell and prefilter are clean and dry.

• W8600F wiring connections are correctly made.

M20806

3

1

2

REMOVING COVER
FROM POWER BOX.

ELECTRONIC

AIR CLEANER

WIRING

COMPARTMENT

BLACK

BROWN

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

OVERLOAD PROTECTION AS REQUIRED.

THE AIR CLEANER CAN BE COMPLETELY ISOLATED FROM

THE ELECTRICAL CIRCUIT OF THE HVAC SYSTEM UNLESS

REQUIRED BY LOCAL CODE TO USE SAME CIRCUIT. ANY

CONVENIENT HOUSE CIRCUIT CAN POWER AIR CLEANER,

REGARDLESS OF ELECTRICAL RATING OF HVAC SYSTEM.

M5707

2

1

2

L1 (HOT)

L2

1

Advertising