17

STEP 2

: Cooktop Burners

a. Remove cooking grills and burner caps.
b. Lift off outer burner spreader.
c. Remove the factory installed natural gas nozzles from the center of the nozzle holders
using a 7mm socket wrench. Replace the LP injector in each nozzle holder. Tighten each
injector properly.

Do not over tighten the injector.

Socket wrench

CAUTION

Handle carefully when removing and replacing gas components. Use proper support to prevent

damage to components.

IMPORTANT:

Each injector has a number indicating its flow diameter printed on the body. Consult the table below for

matching nozzles with cooktop burners.

CAUTION

The Re-ignition system and automatic gas-cut-off system are not equipped on the cooktop

burners. If the flame goes out by accident, need to turn off the valve immediately to cut off the gas supply.

9500BTU

NG: 1.45

LPG: 0.9

16000BTU

NG: 2.0

LPG: 1.18

19000BTU

NG:1.4*2 (outer)+0.8(inner)
LPG:

0.85*2(outer)+0.5(inner)

9500BTU

NG: 1.45

LPG: 0.9

16000BTU

NG: 2.0

LPG: 1.18