Electrical indication, Warning, Caution – Forno Pro-Style Lazio 30 Inch Freestanding Gas Range User Manual Manuel d'utilisation

Page 13: Electrical grounding instructions, Electrical shock hazard

Advertising
background image

11

WARNING:

The installation should be finished step by step. DO NOT remove the washer on the screws at the outside of oven door.

Electrical indication

Your range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance
with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with
the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes.
The power supply must be the correct polarity. Reverse polarity will result in continuous sparking of the electrodes, even
after flame ignition. If there is any doubt as to whether the power supply has the correct polarity or grounded, have it
checked by a qualified electrician.

ELECTRICAL REQUIREMENTS

Electrical Supply

Grounded, 110/120V AC, 60 Hz

Service

15 amp or 20 amp dedicated circuit

Receptacle

3-prong grounding-type

WARNING

Electrical grounding Instructions:

This range is equipped with a three-prong (grounding) plug for your

protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.

Do not

cut or remove the grounding pin from the plug.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

ELECTRICAL SHOCK HAZARD

Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance. Provide appropriate
ground for the appliance. Use copper conductors only. Failure to follow these instructions could result in serious injury or
death.