10095-lp rev b (english) pg03, Lp gas cylinder – Broil King Porta Chef Porta-Chef™ 320 Portable Gas Grill Owner's Manual Manuel d'utilisation

Page 3

Advertising
background image

LP GAS CYLINDER

3

QCC®-1 QUICK CLOSING COUPLING

1. All OMC models are designed to be used with an LP gas

cylinder equipped with the QCC®-1 Quick Closing

Coupling system.

2. The QCC®-1 system incorporates safety features required

by the American National Standards Institute (ANSI) and

the Canadian Standards Steering Committee.

Gas will not flow until a positive connection has been

made.

• A thermal element will shut off the flow of gas betwee

n 240°

and 300° F.

• When activated, a Flow Limiting Device will limit the flow of

gas to 10 cubic feet / hour.

3.

The LP Gas Cylinder is not included with the Gas Grill.

Be sure to purchase one with the QCC® valve. This valve

is recognized by the external threads on the inlet port of

the valve. QCC® equipped cylinders are available from

your Gas Grill Dealer.

NOTE: Any attempt to connect the regulator, by use of

adapters or any other means, to any other valve could

result in damage, fire or injury and may negate the

important safety features in the QCC®-1 system.

SPECIFICATION

1. All LP gas cylinders used with this appliance must

be constructed and marked in accordance with the

Specifications for LP Gas Cylinders of the U.S.

Department of Transportation (D.O.T.) or the National

Standard of Canada, CAN/CSA

-

B339, Cylinders,

Spheres

and Tubes for Transportation of Dangerous

Goods ; and Commission, as applicable

2. The LP gas cylinder used for this appliance must not

have a capacity exceeding 20 lb. (9 kg).

• Approximately 18” (46cm) high and 12” (31cm)

D

iameter.

3. All LP gas cylinders used with this appliance should be

inspected at every filling and re qualified by a licensed

service outlet at the expiry date (10 years), in accordance

with the DOT (USA) and Canadian Transport

Commission (Canada) codes for LP Gas Cylinders.

4.

All LP gas cylinders used with this appliance must be

provided with a shutoff valve terminating in a cylinder

valve outlet No. 510, specified

in the Standard for

Compressed Gas Cylinder Valve Outlet and Inlet

Connection (USA) ANSI/CGA-V-1-1977 (Canada) CSA

B96

.

5. The cylinder supply system must be arranged for vapor

withdrawal.

6.

The cylinder must include a collar to protect the cylinder

valve.

7. The cylinder must be installed as per assembly

instructions.

8.

Never fill the cylinder beyond

80%

full. A fire causing

death or serious injury may occur.

9. The cylinder valve must include a safety relief device

having direct communication with the vapor space of the

cylinder.

HANDLING

1. Government regulations prohibit shipping full LP gas

cylinders. You must take your new cylinder to a LP gas

dealer for filling

2. A filled LP gas cylinder is under very high pressure.

Always handle carefully and transport in the upright

position. Protect the valve from accidental damage.

3.

Do

not tip the LP gas cylinder while connecting it to the

regulator. Fasten the cylinder securely during

transport,

use and storage.

4. If the cylinder is tipped after it is connected to the

regulator,

shut off the

gas,

disconnect the regulator and

have it checked before using it again.

STORAGE

1. Store the LP gas cylinder outdoors in a well-ventilated

place.

2.

Do

not store the LP gas cylinder in direct

sunlight,

near a

source of heat or combustion.

3. If you intend to store the grill

indoors,

disconnect and

remove the LP gas cylinder

first. Disconnected

cylinders

must have a dust cap installed and must not be stored in

a building,

garage or any enclosed area.

4. Keep out of the reach of children.

5.

When

the LP gas cylinder is connected to the gas

grill,

the gas grill and LP gas cylinder must be stored outside

in a well-ventilated place.

OPERATION

1. Never connect your gas grill to an LP gas cylinder

without the regulator

provided,

and NEVER TO AN

UNREGULATED LP GAS SUPPLY

. The regulator

supplied with the barbecue must be used.

2. Always leak test the LP gas cylinder to regulator

connection when connecting the LP gas cylinder to the

appliance. See “Leak T

esting.”

(page 5)

3.

Do not

operate appliance if the smell of LP gas is

present. Extinguish all flame and determine source of LP

gas before proceeding.

Do not

ignite the appliance until

the LP gas leak has been found and sealed.

4. Always shut off LP gas cylinder valve when the appliance

is not in use.

Advertising