Troubleshooting – Maytag MGDB755DW Manuel d'utilisation

Page 12

Advertising
background image

12

TROUBLESHOOTING

If you experience

Possible Causes

Solution

Dryer Operation

Dryer will not run

Door not closed completely.

Make sure the dryer door is closed completely.

Start not touched firmly or held long

enough.

Touch and hold START 2-5 seconds.

Household fuse is blown, circuit

breaker has tripped, or dryer is not

plugged in.

There may be 2 household fuses or circuit breakers for the dryer.

Check that both fuses are intact and tight or that both circuit

breakers have not tripped. Replace the fuses or reset the circuit

breaker. If the problem continues, call an electrician.

Incorrect power supply.

Electric dryers require 240-volt or 208-volt power supply. Check

with a qualified electrician.

Wrong type of fuse.

Use a time-delay fuse.

Dryer will not heat

Household fuse is blown or circuit

breaker has tripped.

The drum may be turning, but you may not have heat. Electric dryers

use 2 household fuses or circuit breakers. Replace the fuses or

reset the circuit breaker. If the problem continues, call an electrician.

Incorrect power supply.

Electric dryers require 240-volt or 208-volt power supply. Check

with a qualified electrician.

The gas supply line valve not open.

For gas dryers, make sure that the valve on the gas supply line is

open.

Unusual Noise

Humming or whining noise

with Steam cycle selected

Water inlet valve on dryer is running.

The water pump on the dryer is used during the Steam function. If

the dryer has just been installed or unused for an extended period,

the pump may be louder and run longer. This is normal.

Thumping noise

Dryer hasn’t been used in a while.

This is normal. The thumping sound should diminish after a few

minutes of use.

Rattling or vibrating noise

A small object caught between the

edges of dryer drum.

Check the front and rear edges of the drum for small objects. Clean

out pockets before laundering.

Dryer isn’t properly leveled.

The dryer may vibrate if not properly installed. See the Installation

Instructions. All four dryer feet should be in firm contact with the

floor.

Clothing is balled up in dryer.

When balled up, the load will bounce, causing the dryer to vibrate.

Separate the load items and restart the dryer.

Clicking noise

Gas valve operating.

On gas dryers, you may hear the gas valve clicking as it opens and

closes. This is normal.

Dryer Results

Clothes are not drying

satisfactorily, clothes are

balling or tangling, or

drying times are too long

Lint screen is clogged with lint.

Clean lint screen before each load.

The exhaust vent or outside exhaust

hood is clogged with lint, restricting air

movement.

Run the dryer on Air Only for 5–10 minutes. Hold your hand under

the outside exhaust hood to check air movement. If you do not

feel air movement, clean exhaust system of lint or replace exhaust

vent with heavy metal or flexible metal vent. See the Installation

Instructions.

The exhaust vent is not the correct

length.

Check that the exhaust vent is not too long or has too many

turns. Long venting will increase drying times. See the Installation

Instructions.

The exhaust vent diameter is not the

correct size.

Use 4" (102 mm) diameter vent material.

The dryer is not level.

Clothes not contacting the moisture sensors during Sensor cycles.

See “Level Dryer” in the Installation Instructions.

The Air Only temperature setting has

been selected.

Select the correct temperature for the types of garments being

dried. See “Cycle Guide.”

First try the solutions suggested here or visit our website at www.maytag.com/product_help –

In Canada www.maytag.ca for assistance and to possibly avoid a service call.

Advertising
Ce manuel est liée aux produits suivants: