Troubleshooting – DCS CP-366 Manuel d'utilisation
Page 21

19
TROUBLESHOOTING
RANGES & COOKTOPS
PROBLEM
POSSIBLE CAUSE
SOLUTION
NON FUNCTIONAL
NO ELECTRICITY OR
GAS SUPPLY
TURN ON GAS SUPPLY VALVE
CHECK CIRCUIT BREAKERS
TECHNICAL
CALL AUTHORIZED SERVICE
ONE OR MORE BURNERS
WILL NOT LIGHT
NO ELECTRICITY
CHECK CIRCUIT BREAKERS
NO GAS
CHECK GAS SUPPLY AT WALL
WRONG GAS
VERIFY GAS TYPE (SEE PAGE 20 FOR LOCATION OF
LABEL
DIRTY BURNERS
CLEAN BURNERS
BURNERS MIS-ALIGNED
ALIGN & REASSEMBLE BURNERS
WATER IN BURNER(S)
DIS-ASSEMBLE & DRY BURNER(S)
DIRTY ELECTRODE
CLEAN BURNER ELECTRODE
TECHNICAL
CALL AUTHORIZED SERVICE
INCORRECT FLAME
SOOTY BURNER FLAME
TOO LARGE OR SMALL
MIS-ALIGNED BURNER ASSY
VERIFY GAS TYPE (SEE LABEL ON BACK)
REALIGN AND RE-ASSEMBLE BURNER ASSY (PAGE 15)
RANGE GRIDDLE & GRILL
PROBLEM
POSSIBLE CAUSE
SOLUTION
NON FUNCTIONAL
NO ELECTRICITY OR GAS SUPPLY
TURN ON GAS SUPPLY VALVE
CHECK CIRCUIT BREAKERS
RADIANT TRAY IMPROPERLY INSTALLED
RE-INSTALL RADIANT TRAY CORRECTLY
TECHNICAL
CALL AUTHORIZED SERVICE
LOW HEAT
PLUGGED BURNER PORTS
SEE PAGE 15 FOR BURNER CLEANING PROCEDURE