100165

Air For Combustion

Air For Heating

THEORY OF

OPERATION

The Fuel System:

The hose/regulator assembly attaches to the propane gas

supply. The propane gas moves through the solenoid valve and out the nozzle.

The Air System:

The motor turns the fan. The fan pushes air into and around

the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System:

The burner control sends voltage to the ignitor. The

ignitor ignites the fuel and air mixture.

The Safety Control System:

This system causes the heater to shut down if the

flame goes out. The motor will continue to run, but no heat is produced.

Motor

Clean
Heated
Air Out
(Front)

Hose/Regulator
Assembly

Figure 2 - Cross Section Operational View

Power
Cord

Cool Air In
(Back)

Ignitor

Fan

Burner Control

Combustion
Chamber

Nozzle

Solenoid
Valve

High Limit