10

100165

SERVICE

PROCEDURE

Cleaning fan

Clean fan every 500 hours of
operation or as needed.
1. Remove screws on side

cover using 7,8 mm (5/16
in.) nut-driver.

2. Remove side cover.
3. Detach the five motor wires

from parts under heater shell.
Be sure to detach only wires
coming from motor.
The five motor wires are:
• white wire—to terminal

board

• red wire—to terminal

board

• blue wire—to thermal

switch wire

• blue wire—to solenoid

valve

• green wire—to grounding

screw on shell

4. Remove fan guard from rear

of heater.

5. Reach into rear of heater

shell. Carefully pull motor
wires through hole in
bottom of shell.

Note:

Pull

wires through hole one at a
time.

6. Remove nuts and mounting

bolts holding motor mount
to shell. Use 9,5 mm (3/8")
nut-driver and 11,1 mm
(7/16") wrench.

7. Carefully pull motor and fan

out of shell.

IMPORTANT:

Be careful

not to damage fan. Do not
set motor and fan down
with the weight resting on
fan. This could damage fan
pitch.

8. Turn motor and fan around.

Place motor and fan into
shell backwards.

Note:

Motor will go into shell first
(see Figure 8, page 11).

Figure 7 - Location of Fan and Motor

Motor
Wires

Mounting
Bolts

Motor
Mount

WARNING ICON

G 001

WARNING

Never service heater while it is plugged in, connected to
propane supply, operating, or hot. Severe burns and
electrical shock can occur.

Figure 6 -

Location of Motor Wires

Grounding Screw

Thermal
Switch Wire

Terminal
Board

Solenoid
Valve

Relay

Advertising