Making the lp conversion (cont.), Adjust burner flames, Installation instructions – GE JGP329DETBB Manuel d'utilisation

Page 16: Making the lp conversion, Cont.)

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

Installation Instructions

MAKING THE LP CONVERSION

(CONT.)

ADJUST BURNER FLAMES

Turn all burners full on and check the flames.
They should be blue in color with some yellow
tipping at the ends of the flame. Foreign

particles in the gas line may cause on orange

flame at first, but this will soon disappear.

NOTE: For the 15,000 BTU/HR burner (on some
models) the cooktop burner knob should be

turned to the setting before the lowest setting.
This will ensure that the entire burner is
operating.

E Turn the cooktop burner knob to the lowest

setting while observing the flame.

Adjust the low flame setting using the valve bypass
screw as follows:

Low-setting adjustments must be made with two

other burners in operation on a medium setting.

This prevents the low flame from being set too low,

resulting in the flame being extinguished when
other burners are turned on.

E To adjust the flame, remove the knobs. Insert

a screwdriver through the access hole in valve
switch. Engage
adjustment screw in
valve. Refer to the
illustration below that
matches the adjustment
screw location for your
model.

• If the flames were too

small or fluttered, open
the valve more than
the original setting.

• If the flames blew

away from the burner,
close the valve more
than the original
setting.

E Make the adjustment by slowly turning the

screw until flame appearance is correct.

Note: Some models may contain a silicone shield

which covers the valve switch and access hole. A
flashlight may be required to locate the access hole. To
access the valve adjusting screw, push the screwdriver
through this shield. A1^er adjustment, reseat the
shield around the switch hub with your fingers, a1^er
withdrawing the screwdriver.

Reseat silicone shield

E Testing Flame Stability:

Test 1 - Turn the knob from "HI" to the lowest

setting quickly. If the flame goes out
at the lowest setting, increase the
flame size and test again.

Test 2 - With the burner on the lowest setting,

open and close the cabinet door
under the cooktop. If the flame is
extinguished by the air currents
created by the door movement,
increase the flame height and test
again.

E Flame Recheck:

After the adjustment is made, turn all burners off.

Ignite each burner individually. Observe the flame

at the "HI" position. Rotate the valve to the lowest
setting and be sure that the flame size decreases
as the valve is rotated counterclockwise.

TO CONVERT THE COOKTOP BACK TO NATURAL

GAS, REVERSE THE STEPS UNDER MAKING THE LP
CONVERSION.

Once the conversion is complete and checked
ok, fill out the LP sticker and include your name,
organization and date conversion was made. Apply
the sticker near the cooktop gas inlet opening to
alert others in the future that this appliance has
been converted to LP gas. If converting back to
natural gas from LP, please remove the sticker so
others know the appliance is set to use natural gas.

16

Advertising