How to use your unit – Craftsman 919.72413 Manuel d'utilisation

Page 13

Advertising
background image

13 - ENG

A08394

1. Make sure the On/Auto/Off lever

is in the "Off" position.

NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.

2. Plug the power cord into the

correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)

3. Open the drain valve fully

(counterclockwise) to permit
air to escape and prevent air
pressure build up in the air tank
during the break-in period.

NOTE: Always drain tank on a
washable surface or in a suitable
container to prevent damaging or
staining surfaces.

4. Move the On/Auto/Off lever

to "On/Auto" position. The
compressor will start.

5. Run the compressor for 15

minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.

6. After 15 minutes, close the drain

valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.

The compressor is now ready for use.

Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the
air compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.

Before First Start-up

Risk of Unsafe
Operation. Serious

damage may result if the following
break-in instructions are not
closely followed.

This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.

How to Use Your Unit

How to Stop:

1. Set the On/Auto/Off lever to

"Off".

Check Valve

Advertising