19- ENG

A14411

6. Assemble the regulator and ori-

ent as shown.

NOTE: Arrow indicates flow of air.

Make sure it is pointing in the direc-

tion of air flow.

7. Reapply pipe sealant to outlet

pressure gauge and quick con-

nect.

8. Reassemble outlet pressure

gauge and quick connect. Orient

outlet pressure gauge to read

correctly. Tighten quick connect

with wrench.

To Replace Regulator

1. Release all air pressure from air

tank. See "To Drain Tank" in the

Maintenance section.

2. Set the On/Auto/Off lever to

"OFF" and unplug unit.

3. Remove the outlet pressure

gauge and quick connect (if

equipped) from the regulator.

4. Remove the regulator.
5. Apply pipe sealant tape to the

nipple.

Nipple

Outlet

Pressure

Gauge

Quick

Connect

Regulator

Regulator

Arrow

Regulator

Advertising