Extension Cords

Using extension cords is not recom-
mended. The use of extension cords
will cause voltage to drop resulting
in power loss to the motor and over-
heating.
Instead of using an extension cord,
increase the working reach of the air
hose by attaching
If an extension cord must be used,
be sure it is:

a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product

in good condition

no longer than 50 feet

12 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE
14 OR 16 AWG.)

Voltage and Circuit Protection

Refer to the Parts Manual for the
voltage and minimum branch circuit
requirements.

Risk of Unsafe

Operation. Certain

air compressors can be operated

on a 15 amp circuit if the following

conditions are met.
1. Voltage supply to circuit must

comply with the National
Electrical Code.

2. Circuit is not used to supply any

other electrical needs.

3. Extension cords comply with

specifications.

4. Circuit is equipped with a 15

amp circuit breaker or 15 amp
time delay fuse.

NOTE: If com-

pressor is connected to a circuit
protected by fuses, use only time
delay fuses. Time delay fuses
should be marked "D" in Canada
and "T" in the US.

If any of the above conditions can-
not be met, or if operation of the
compressor repeatedly causes inter-
ruption of the power, it may be nec-
essary to operate it from a 20 amp
circuit. It is not necessary to change
the cord set.