How to use your unit – Craftsman 919.724321 Manuel d'utilisation

Page 14

Advertising
background image

14- ENG

A14411

Cooling System (not shown): This

compressor contains an advanced

design cooling system. At the heart of

this cooling system is an engineered

fan. It is perfectly normal for this fan

to blow air through the vent holes

in large amounts. You know that the

cooling system is working when air is

being expelled.
Air Compressor Pump (not shown):

Compresses air into the air tank.

Working air is not available until the

compressor has raised the air tank

pressure above that required at the

air outlet.
Check Valve: When the air compres-

sor is operating, the check valve is

"open", allowing compressed air to

enter the air tank. When the air com-

pressor reaches "cut-out" pressure,

the check valve "closes", allowing air

pressure to remain inside the air tank.

Pressure Release Valve: The pres-

sure release valve located on the side

of the pressure switch, is designed to

automatically release compressed air

from the compressor head and the

outlet tube when the air compressor

reaches "cut-out" pressure or is shut

off. The pressure release valve allows

the motor to restart freely. When

the motor stops running, air will be

heard escap-

ing from this

valve for a

few seconds.

No air should

be heard

leaking when

the motor is

running, or

continuous

leaking after unit reaches "cut-out"

pressure.

Check Valve

Pressure

Release

Valve

Before Starting

Break-in instructions

Risk of Unsafe

Operation. Serious

damage may result if the follow-

ing break-in instructions are not

closely followed.
This procedure is required

before

the air compressor is put into service
and when the check valve or a com-
plete compressor pump has been
replaced.
1. Make sure the On/Auto/Off lever

is in the "OFF" position.

NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2. Plug the power cord into the

correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)

3. Open the drain valve fully (coun-

ter-clockwise) to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.

NOTE: Always drain tank on a wash-
able surface or in a suitable container
to prevent damaging or staining sur-
faces.
4. Move the On/Auto/Off lever to

"ON/AUTO" position. The com-
pressor will start.

How to Use Your Unit

How to Stop:

1. Set the On/Auto/Off lever to

"OFF".