METROPOLITAN INSTALLATION MANUAL

ITEM# TW-MT-10PS-HW-HD

TIMER INFORMATION

WarmlyYours towel warmers include our programmable timer for

efficient, economical use.

Operation

Towel warmer runs at 100% power and will reach temperatures

between 100° F and 140° F depending on the following factors:

running time, number of towels, type of towels and ambient room

temperature. For optimal performance, WarmlyYours recommends

using Automatic Mode.

Automatic Mode

The programmable timer allows up to 14 events or two ON-OFF

cycles per day. Easy programming allows you to set intervals of

operation for each day of the week. Flip the panel switch up to

access programming controls. Refer to control diagram for switch

location.

Manual Mode

Timer can be set to operate in manual mode to function as a simple

ON-OFF switch.

HOT (black or blue)

NEUTRAL

(white or brown)

GROUND (green/yellow)

Control diagram

2” x 4” ELECTRICAL

BOX FOR TIMER

2” x 4” ELECTRICAL BOX

TOWEL WARMER

HOT LOAD

(black or blue)

LINE

(black)

NEUTRAL

(white)
LOAD

(blue)

120 ac HOT

NEUTRAL

GROUND

GROUND

(green/yellow)

120 VOLT TIMER

NEUTRAL LOAD

(white or brown)