• When re-assembling the pump, be sure to align the raised

key on the impeller flange to the matching notch in the face

of the pump flange.

Winter Storage – If concerned about possible freeze

damage, disconnect the threaded collar on the fitting and

remove the pump from the filter (be careful not to lose the flat

rubber washer). Clean the pump and inlet screens with fresh

water and store the pump in a frost-free location. the pump

can be run during freezing weather, if desired, but the pump

should be removed in the event of a power failure to prevent

any freeze damage to either the pump or the piping.

• If your rotor assembly impeller and internal pump body have

excessive scale build-up, clean with a mild acid, such as

white vinegar or non-abrasive calcium, lime and rust remover

product, using a sponge or soft-bristled brush that won’t

scratch the stainless steel. removing scale build-up will allow

your pump to run like new again.

1

3

2

4

trOUbleShOOting

Reduced Water Flow

– pump or plumbing may be clogged. it may be

necessary to clean the filter screens and impeller.

• Pump Hums and Doesn’t Push Water

– pump or plumbing may be clogged. it may be

necessary to clean the filter screens and impeller

– remove the water chamber cover and inspect and

clean the impeller rotor assembly and internal pump

body

– Make sure nothing is blocking or wrapped around the

impeller.

– Make sure the pump is receiving the correct voltage.

• Pump Not Working

– the ground-fault circuit-interrupter (gfCi) may

have tripped

– the pump is not receiving the correct voltage.

– remote Control Not working

– Check to make sure the switch located on the receiver

is in the remote Control position.

– Check the label on the back of the receiver and

transmitter to make sure they are paired to the same

frequency.

– Check to make sure the battery is installed properly.

replace battery if needed.

.

For more information about our company or products, please visit our website at www.aquascapeinc.com

or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426

©2012 Aquascape, Inc. • All Worldwide Rights Reserved

45015.110177

I n S t R u c t I O n S e t e n t R e t I e n

45015 AquaSurge PRO Instruction Manual 11-11.indd 8

12/7/11 5:03 PM

Advertising