Safety information

WARNING: Risk of electric shock – This pump

has not been approved for use in swimming

pool or marine areas.

WARNING: To provide continued protection

against risk of electric shock, connect to properly

grounded, ground fault circuit interrupter (GFCI)

outlets only, using the following guidelines:

(A) Have a qualified electrician install a properly

grounded receptacle outlet, acceptable for outdoor

use and protected from snow and rain.

(b) inspect cord before using.
(C) Do not use extension cords.
(D) Any wiring of pumps should be performed by a

qualified electrician to ensure code compliance

and user safety.

(e) Unplug pump at receptacle outlet when not

in use or before removal from pond.

(f) to reduce risk of electrical shock, all wiring

and junction connections should be made per local

codes. requirements may vary depending on usage

and location.

(g) the power cable should be protected at all times to

avoid punctures, cuts, bruises and abrasions.

(H) Never handle power cords with wet hands.
(i) Do not remove cord and strain relief. Do not connect

conduit to pump.

(J) Do not use power cable to lift pump.

inStallation

• Always operate the pump fully submerged. Failure to do so

will overheat the pump and cause it to fail, thus voiding the

warranty. Do Not operAte Dry!

• Use only in fully assembled state, and be sure that both

the upper and lower cage screens are snapped together.

failure to operate the pump without the filter cage closed

will allow large debris to enter the pump, causing the pump

to fail and voiding the warranty.

• Do not wear loose clothing that may become entangled in

the impeller or other moving parts.

• Keep clear of suction and discharge openings. DO NOT

insert fingers in pump with power connected.

• Do not pump hazardous materials or liquids, such as oil,

saltwater or organic solvents.

• Do not block or restrict discharge.
• Products returned must be cleaned, sanitized, or

decontaminated, as necessary prior to shipment so as

to ensure that employees will not be exposed to health

hazards in handling said material. All applicable laws and

regulations shall apply.

ImPORtANt: Aquascape, Inc. is not responsible

for losses, injury, or death resulting from a failure

to observe these safety precautions, misuse or

abuse of pumps or equipment.

aquaforCe

®

SPeCifiCationS

• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for use with water only
• Input Amps & Wattage: See chart on next page

Advertising