Installation, Owner's responsibilities – Blodgett CNV14G Manuel d'utilisation

Page 8

Advertising
background image

Installation

4

Owner's Responsibilities

Installation responsibilities prior to service

startup inspection
You are entitled to a free startĆup inspection serĆ

vice by our factory ASAP. Before a factory repreĆ

sentative arrives to perform a startup procedure,

the owner must already have satisfied the followĆ

ing requirements.

1. Oven(s) are uncrated, stacked (if applies) and

put in place.
NOTE: Please refer to Leg Attachment and

Stacking.

Maximum shelf loading - 100 lbs (45.5 Kg)

RATINGS - GAS APPLIANCES - CNV14G/AA

Gas Type

Gas Input

Voltage

Phase

Amps

Motor

U.S. and Canadian Installations

Natural

65,000 BTU/Hr

208Ć240

1

15

1/2HP 208Ć240VAC, 50/60 Hz

120

1

15

1/2HP 208Ć240VAC, 50/60 Hz

Propane

65,000 BTU/Hr

208Ć240

1

15

1/2HP 208Ć240VAC, 50/60 Hz

120

1

15

1/2HP 208Ć240VAC, 50/60 Hz

3/4" FNPT connector for all U.S. and Canadian installations

RATINGS - ELECTRIC APPLIANCES - CNV14E/AA

Voltage

Hz

Phase

Max Load (amps)

Motor

L1

L2

L3

208

60

1

89

89

-

1/2HP 208Ć240VAC, 50/60 Hz

208

60

3

52

52

52

1/2HP 208Ć240VAC, 50/60 Hz

240

60

1

82

82

-

1/2HP 208Ć240VAC, 50/60 Hz

240

60

3

47

47

47

1/2HP 208Ć240VAC, 50/60 Hz

480

60

3

23

23

23

1/2HP 208Ć240VAC, 50/60 Hz

380/220

50

3

25

25

25

1/2HP 208Ć240VAC, 50/60 Hz

415/240

50

3

27

27

27

1/2HP 208Ć240VAC, 50/60 Hz

400/230

50

3

26

26

26

1/2HP 208Ć240VAC, 50/60 Hz

Advertising
Ce manuel est liée aux produits suivants: