Installation

12

Gas Connections

PRESSURE REGULATION AND TESTING
The gas pressure to the appliance must be rated

for each appliance while the burners are on. A sufĆ

ficient gas pressure must be present at the inlet to

satisfy these conditions. Refer to the table below

for correct gas pressure.
Each appliance has been adjusted at the factory

to operate with the type of gas specified on the ratĆ

ing plate attached to the right side of the apĆ

pliance.
Each oven is supplied with a regulator to maintain

the proper gas pressure. The regulator is essenĆ

tial to the proper operation of the oven and

should not be removed.
DO NOT INSTALL AN ADDITIONAL REGULATOR

WHERE THE UNIT CONNECTS TO THE GAS

SUPPLY UNLESS THE INLET PRESSURE IS

GREATER THAN 14" W.C. (1/2 PSI) (37mbar).
The oven and its individual shutoff valve must be

disconnected from the gas supply piping system

during any pressure testing of that system at test

pressures in excess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply

piping system by closing its individual manual

shutoff valve during any pressure testing of the

gas piping system at test pressures equal or less

than 1/2 psig (3.45kPa).
Prior to connecting the appliance, gas lines

should be thoroughly purged of all metal filings,

shavings, pipe dope, and other debris. After conĆ

nection, the appliance must be checked for corĆ

rect gas pressure.
U.S. and Canadian Installations
Installation must conform with local codes, or in

the absence of local codes, with the National Fuel

Gas Code, NFPA54/ANSI Z223.1-Latest Edition,

the Natural Gas Installation Code CAN/CGAĆ

B149.1 or the Propane Installation Code, CAN/

CGAĆB149.2 as applicable.
General Export Installations
Installation must conform with Local and National

installation standards. Local installation codes and/

or requirements may vary. If you have any questions

regarding the proper installation and/or operation of

your appliance, please contact your local distributor.

If you do not have a local distributor, please call

Blodgett Combi at 0011Ć802Ć860Ć3700.

GAS PRESSURE

Gas

T

Inlet

P

Orifice Size at Sea Level

Manifold Pressure

Type

Pressure

Hot Air

Steam

Hot Air

Steam

U.S. and Canadian Installations

Natural

7-14" W.C.

.0531" dia

.042" dia

3.5" W.C.

3.5" W.C.

Propane

12-14" W.C.

.032" dia

.026" dia

10.0" W.C.

10.0" W.C.

Advertising