10 optional nz64 blower installation, For complete instructions, see blower kit, Wide by 10 – Napoleon Fireplaces High Country 6000 - NZ6000 Manuel d'utilisation
Page 30

W415-0594 / E / 10.19.12
30
6.10 OPTIONAL NZ64 BLOWER INSTALLATION
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE NATIONAL ELECTRIC CODE ANSI/NF NO. 70-CURRENT (IN THE
UNITED STATES), OR WITH THE CURRENT CSC22.1 CANADIAN ELECTRIC CODE (IN CANADA).
WARNING:
BLOWER
CONNECTION ONL
Y
AVERTISSEMENT
:
CONNEXION DE LA
SOUFFLERIE
SEULEMENT
AVERTISSEMENT
:
AIR COMBURANT
SEULEMENT
WARNING:
COMBUSTION AIR
ONLY
L2
L1
Housing must be
mounted
horizontally
Blower housing may be
installed inside a home
that has sufficient air flow.
Optional summer fan
switch (not supplied)
Blower may be installed
on either side of the unit
10' length of venting
supplied
Blower housing may
be installed on an
outside wall to bring
in fresh air for hot air
circulation (not
recommended in
colder climates)
FOR COMPLETE INSTRUCTIONS,
SEE BLOWER KIT.
12
3
/
8
"
10
1
/
2
"
OUT
SIDE W
ALL
INSIDE W
ALL
LEVEL SURF
ACE BLOWER HOUSING
W
ARNING:
COMBUSTION AIR
W
ARNING:
BLOWER
CONNECTION ONL
Y
AVERTISSEMENT
:
CONNEXION DE LA
SOUFFLERIE
SEULEMENT
Route a 120 Volt, 60Hz electrical supply (not supplied) from the electrical box on the side of the appliance to
the electrical box on the blower housing.
The appliance comes complete with a safety switch and a thermally activated switch.
A.
Remove the template.
B.
Position the blower to an inside or outside wall into a
framed opening 12
3
/
8
” wide by 10
1
/
2
” high. (Outside
wall not recommended in colder climates as cold air
may be drawn into the house when the appliance is
off.)
The blower housing should be installed onto a level sur-
face large enough to support the blower assembly.
Allow for fi nishing material when securing the blower
housing, as the grill mounts to the housing.
NOTE: Consideration should be made for blower location as the closer to the appliance the greater the
air fl ow noise will be. Blower may be installed on either side of the appliance.