Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed. Curtains, above the appliance, must not be positioned lower than the 5" distance required
for the 2" combustible mantel. These same requirements apply to any combustibles protruding on either side
of the appliance.

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

5.4 MINIMUM MANTEL CLEARANCES

APPLIANCE

RECESS OR
ALCOVE
AREA

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.

Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.

The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.

71.2

ENCLOSURE
AREA

5.3 ALCOVE