Warning – Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation
Page 35

35
W415-0773 / F / 08.26.13
EN
STAND-OFF ASSEMBLY
Bend and secure the top stand-off(s) as illustrated:
A
B
C
6.1.1 MINIMUM FRAMING DIMENSIONS
37 3/4"
959mm
38 3/4"
984mm
3" 76mm
5 1/2" 140mm
14 1/2"
368mm
42 1/4" 1080mm
(REAR EXIT)
63" 1600mm
(TOP EXIT)
3 1/2"
89mm
MAX
1 1/2"
38mm
MAX
14"
356mm
MINIMUM
GAS
INLET
LOCATION
FINISHING
MATERIAL
ENCLOSURE
TOP
TOP EXIT INSTALLATION
SHOWN
FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED
ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
!
WARNING
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" (25mm) away from
the side of the appliance.
Thereafter, the depth of any protrusions must be equal to or less than the distance from the side of the appliance up to a
depth of 6" (152mm), after which no greater clearance than 6" (152mm) is required. This can be considered a side wall with
no length boundary.
36 3/4"
933mm
37 3/4"
959mm
52"
1321mm
OUTSIDE
CHASE
INSIDE
CHASE
PROTRUSION
SIDE
WALL
14 1/2"
368mm
37 3/4" 959mm
37 3/4" 959mm
14 1/2"
368mm
2" 51mm
2" 51mm
4" 102mm
4" 102mm
6" 152mm