3.8 TOP EXIT HORIZONTAL TERMINATION
(H
T
) < (V
T
)
Simple venting configuration
(only one 90° elbow)
See graph to determine the required vertical rise V
T
for the required horizontal run H
T
.
0
2.5
(0.8)
5
(1.5)
7.5
(2.3)
10
(3.1)
12.5
(3.8)
15
(4.6)
40 (12.2)
10 (3.1)
20 (6.1)
30 (9.1)
17.5
(5.3)
20
(6.1)
39 (11.9)
HORIZONTAL VENT RUN PLUS OFFSET IN
FEET (METERS) H
T
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 40 feet (12.2m)
Example 1:
V
1
= 3 FT (0.9m)
V
2
= 8 FT (2.4m)
V
T
= V
1
+ V
2
= 3FT (0.9m) + 8FT (2.4m) = 11FT (3.4m)
H
1
= 2.5 FT (0.8m)
H
2
= 2 FT (0.6m)
H
R
= H
1
+ H
2
= 2.5FT (0.8m) + 2FT (0.6m) = 4.5 FT (1.4m)
H
O
= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT (1.6m)
H
T
= H
R
+ H
O
= 4.5FT (1.4m) + 5.4FT (1.6m) = 9.9 FT (3m)
H
T
+ V
T
= 9.9FT (3m) + 11FT (3.4m) = 20.9FT (6.4m)
Formula 1:
H
T
< V
T
9.9FT (3m) < 11FT (3.4m)
Formula 2:
H
T
+ V
T
< 40 FT (12.2m)
20.9FT (6.4m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
90°
90°
90°
V
1
V
2
H
1
H
2
The shaded area within the lines represents
acceptable values for H
T
and V
T
0
2.5
(0.8)
5
(1.5)
7.5
(2.3)
10
(3.1)
12.5
(3.8)
15
(4.6)
40 (12.2)
10 (3.1)
20 (6.1)
30 (9.1)
17.5
(5.3)
20
(6.1)
39 (11.9)
GD36
BGD36
REQUIRED
VERTICAL
RISE IN FEET
(METERS)V
T
HORIZONTAL VENT RUN PLUS OFFSET IN
FEET (METERS) H
T
16.2B
REQUIRED
VERTICAL
RISE IN FEET
(METERS)V
T