Thermistor Check

Check Voltage at Pin #4 and #5 of CN5

Tester Check = DC 1.6V

If it ready 5V, check if its connector is engaged

properly.
DR Ready Check

Check Voltage at Pin #1 and #5 of CN7

Tester Check = DC 3.3V

Water Sensor Check

Check Voltage and Frequency at Pin #6 and #5

of CN5

Reset water level = DC1.6V, 26.0KHz

Check Voltage and Frequency at Pin #7 and #5 of CN5

Reset water level = DC1.6V, 26.0KHz

DR Ready Check

Check Voltage at Pin #1 and #5 of CN2

Tester Check = DC 3.3V

PROBLEM CHECKING AND METHOD OF PCB (WF461AS*)

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

£

¬

CN6

£CN5 ª

£

CN

7

§

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING