Thermistor Check

Check Voltage at Pin #4 and #5 of CN5

Tester Check = DC 1.6V

If it ready 5V, check if its connector is engaged

properly.

Water Sensor Check

Check Voltage and Frequency at Pin #6 and #5 of CN5

Reset water level = DC1.6V, 26.0KHz

Check Voltage and Frequency at Pin #7 and #5 of CN5

Reset water level = DC1.6V, 26.0KHz

PROBLEM CHECKING AND METHOD OF PCB (WF461AB*)

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING