Trouble shooting, Problem checking and method of pcb (wf461ab*), Warning – Samsung WF431ABP-XAA Manuel d'utilisation
Page 22
Advertising

22
Thermistor Check
Check Voltage at Pin #4 and #5 of CN5
Tester Check = DC 1.6V
If it ready 5V, check if its connector is engaged
properly.
Water Sensor Check
Check Voltage and Frequency at Pin #6 and #5 of CN5
Reset water level = DC1.6V, 26.0KHz
Check Voltage and Frequency at Pin #7 and #5 of CN5
Reset water level = DC1.6V, 26.0KHz
PROBLEM CHECKING AND METHOD OF PCB (WF461AB*)
- If you plug in the power cord and turn Power S/W on, memorized data is displayed.
If any data is not displayed, check the followings.
TROUBLE SHOOTING
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
WARNING
WF431ABP-03015A-03_EN.indd 22
2012-01-17 �� 5:22:23
Advertising