Trouble shooting, Problem checking and method of pcb (wf461), Warning – Samsung WF431ABP-XAA Manuel d'utilisation

Page 21

Advertising
background image

21

Hall Sensor Check

Check Voltage at Pin #4 and #3 of CN3

Tester Check = DC 0V or 1.3V

Check Voltage at Pin #4 and #2 of CN3

Tester Check = DC 0V or 1.3V

Motor Check

Resistance at Pin #1 of #2 of CN5 = 12Ω

Resistance at Pin #2 of #3 of CN5 = 12Ω

Resistance at Pin #3 of #3 of CN5 = 12Ω

Door Lock Check

Check AC Voltage at Pin #1 of CN6 and Pin #2

of CN6

When Door Lock = AC 120V

Drain Motor Check

Check Voltage at Pin #1 of RY1 and Pin #3 of CN1

When Drain Pump operates = AC 120V

Water Valve Check

Check Voltage at Pin #1 of RY1 and Pin

#6,7,8,9,10 of CN1

When Each Valve operates = AC 120V

AC Power Check

Check Voltage at Pin #1 of CN6 and #1 of RY1

When Set Power On = AC 120V

WASH Heater Relay Check

Check Voltage at Pin #1 of RY1 and Pin #2 of RY13

When Wash Heater Relay operates = AC 120V

Dry Heater Relay Check

Check Voltage at Pin #1 of RY1 and Pin #2 of RY2

When Dry Heater Relay operates = AC 120V

PROBLEM CHECKING AND METHOD OF PCB (WF461)

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING