Battery, Load solar module – Samlex America SMC-20 Manuel d'utilisation

Page 8

Advertising
background image

8 | SAMLEX AMERICA INC.

SeCtIOn 3 |

Installation

An additional external fuse (not provided) must be connected to the battery connection
cable, close to the battery pole. the external fuse prevents cable short circuits. A 40A
fuse can be used for all controller types.

!

WARninG!

Danger of explosion from sparking! Danger of electric shock! Solar modules generate
electricity under incident light. the full voltage is present, even when the incident light
levels are low.
- Protect the solar modules from incident light during installation, e.g. cover them.
- never touch uninsulated cable ends.
- Use only insulated tools.
- ensure that all loads to be connected are switched oFF. if necessary, remove the

fuse.

- connections must always be made in the sequence described below.

3

4

5

1 2a

2b 2c

2d

2

1

3

A+

A-

M

M-

battery

(40A fuse at A+)

L

L-

Load

Solar

Module