iSSUe

cAUSe

ReMeDy

LoAD CANNoT be
oPerATeD
+
INfo LeD (1)
fLASheS reD
+
greeN LeD (2d)
fLASheS

Load output is
switched off due
to excessive battery
voltage

The load output automatically
switched on again as soon as the
battery voltage lies within the per-
missible range

Incorrect grounding

Check the grounding. grounding
is allowed only on the Negative
battery Terminal

external charging
source is not voltage-
limited

- Check the external charging
source
- If necessary, switch off external
charging source

LoAD CANNoT
be oPerATeD
+
INfo LeD (1)
ILLUMINATeS greeN

Defective load or
installation error

- Connect load correctly
- replace load

bATTery IS
NoT ChArgeD

Solar module not
connected

Connect the solar module

Solar module
connected with
incorrect polarity

Connect the solar module with
the correct polarity

Short circuit at solar
module input

Correct the cause of the short
circuit

Incorrect solar module
voltage

Use a solar module of the speci-
fied voltage

Solar module defective

replace the solar module

bATTery DISPLAy
jUMPS qUICKLy

Large pulse current

Adjust the current consumption to
match the battery capacity

battery is defective

replace the battery