STEINEL IS 240-120 Manuel d'utilisation
Page 11

www.steinel.net
(800) 852-4343
www.steinel.net
(800) 852-4343
20
No power at
the sensor
Lights do
not switch
ON
Breaker has tripped;
light switch is in OFF
position
Short circuit
Light level setting is in
nighttime mode during
daytime operation
Lamp burned out
Power is off
Breaker has tripped
Detection zone not
correctly adjusted
Reset breaker, turn
light switch to ON
position, check
wiring with voltage
tester
Check for proper
wiring connections
Adjust light level
setting
Replace lamp
Turn power on at
circuit breaker
Reset breaker
Readjust
Problem
Cause
Remedy
Troubleshooting
21
Troubleshooting
Lights do
not switch
OFF
Lights keep
switching
ON/OFF
Lights
switch ON
without
obvious
movement
Abundant heat from
fi xture is within detection
zone and keeps lights
on as a result of
temperature change
Set to 4 hour override
mode
Switched on light is
within detection zone
Animals moving in
detection zone
Wind is moving trees
and bushes in the
detection zone
Cars in the street are
detected
Sudden temp changes
due to weather (wind,
rain, snow) or exhaust
air from fans or open
windows
Readjust zone or
apply shroud
Turn sensor off at
switch
Adjust detection
zone or apply
shrouds, increase
distance
Adjust zone or
apply shrouds
Adjust zone or
apply shrouds
Adjust zone or
apply shrouds
Adjust detection
zone or install in a
different place
Problem
Cause
Remedy