Page 29: A-20

A-20
INSTALLATION
POWER WAVE® AC/DC 1000® SD
A-20
FIGURE A.13 – SOUDURES CIRCONFÉRENTIELLES À ARCS MULTIPLES
ARC No.1
ARC No.2
CIRCULA
TION
DU C
OURANT
Travail No.1
aDétection No.1
Travail No.2
Détection No.2
SOURCE
D’ALIMENTATION
No.1
MAL
LA CIRCULATION DU COURANT
PROVENANT DE L’ARC No.1 AFFECTE
LE FIL DE DÉTECTION No.2.
LA CIRCULATION DU COURANT
PROVENANT DE L’ARC No.2 AFFECTE
LE FIL DE DÉTECTION No.1.
AUCUN DES DEUX FILS DE DÉTECTION
NE CAPTE LA TENSION DE TRAVAIL
CORRECTE, CE QUI PROVOQUE UNE
INSTABILITÉ DE L’ARC DURANT LE
DÉMARRAGE ET LE SOUDAGE.
SOURCE
D’ALIMENTATION
No.1
ARC No.1
Travail No.1
Détection No.1
CIRCULA
TION DU
COURANT
CIRCULA
TION
DU C
OUR
ANT
ARC No.2
Travail No.2
Détection No.2
SOURCE
D’ALIMENTATION
No.2
MIEUX
LE FIL DE DÉTECTION No.1 N’EST
AFFECTÉ QUE PAR LA CIRCULATION DU
COURANT PROVENANT DE L’ARC No.1.
LE FIL DE DÉTECTION No.2 N’EST
AFFECTÉ QUE PAR LA CIRCULATION DU
COURANT PROVENANT DE L’ARC No.2.
DU FAIT DES CHUTES DE TENSION AU TRAVERS
DE LA PIÈCE À SOUDER, LA TENSION DE L’ARC
PEUT ÊTRE FAIBLE, CE QUI NÉCESSITE UNE
DÉVIATION DES PROCÉDURES STANDARD.
ARC No.1
Détection No. 1
Détection No. 2
ARC No.2
Travail No. 1
Travail No. 2
SOURCE
D’ALIMENTATION
No.1
SOURCE
D’ALIMENTATION
No.2
CIRCUL
ATION DU COURA
NT
IDÉAL
LES DEUX FILS DE DÉTECTION SE TROUVENT
HORS DES PASSAGES DE COURANT.
LES DEUX FILS DE DÉTECTION DÉTECTENT
LA TENSION DE L’ARC AVEC PRÉCISION.
PAS DE CHUTE DE TENSION ENTRE L’ARC
ET LE FIL DE DÉTECTION.
MEILLEURS DÉMARRAGES, MEILLEURS
ARCS, RÉSULTATS LES PLUS FIABLES.
SOURCE
D’ALIMENTATION
No.2