Robertshaw RS6320C Manuel d'utilisation
Page 11

11
Default Settings for RS5220C, RS6220C
and RS6320C
The RS5220C and RS6320C series are programmable thermostats
and are preprogrammed with a recommended schedule. The schedule is
designed to lower energy costs year-round.
Setting Time and Day for the RS5220C,
RS6220C and RS6320C
To adjust the time and day settings press the SET TIME button. The hour
will flash. To change the settings:
1. Use the and buttons to change the flashing number.
2. Press the SET TIME button to move through hours, minutes and days
of week.
3. Make changes as needed. They will be saved automatically.
NOTE: The thermostat will not correct for Daylight Saving Time.
Installation Test Utility
WARNING: The installation test procedures
can damage the heating/cooling equipment
if used incorrectly. These procedures
should only be performed by trained
HVAC personnel.
The following instructions may be used to test the heating/cooling
system for correct function.
To enter the test mode press and hold and
for five seconds.
Short Cycle protection is disabled when using the test utility.
Push the and or Start/Stop schedule buttons at any time to
exit test mode.
In the test mode:
Press to force the fan on or off.
Pressing
repeatedly will allow testing of the system modes. See
following tables. The display will show appropriate animated icons.
Temperature Settings
Winter (Heating)
Summer (Cooling)
Morning (6:00 am)
70 °F (21 °C)
78 °F (25 °C)
Day (8:00 am)
62 °F (17 °C)
85 °F (29 °C)
Evening (6:00 pm)
70 °F (21 °C)
78 °F (25 °C)
Night (10:00 pm)
62 °F (17 °C)
82 °F (28 °C)