Examples (speaker cabinets connected in parallel), Replacement tube selection & bias, Specifications – Yorkville Sound All-Tube Guitar Amplifier YS1036 Manuel d'utilisation

Page 8

Advertising
background image



Specifications

Type

YCS100 Tube Guitar Amplifier

Minimum Impedance (ohms)

2 (30-watt mode), 4 (100-watt mode)

Input Channels

3

Channel input

1/4 inch phone

Channel 1, 2, 3 - Controls

Gain, Volume,Treble, Mid, Bass, Reverb, and Effects

Channel 1, 2 - Switches

Boost, Scoop and Modern

Channel 3 - Switches

Boost, Bright and Modern

Channel 2 - Inputs

Shares Ch 1 input

Channel 3 - Inputs

Shares Ch 1 input

Channel Switching

Yes, footswitchable

Line Out (type / configuration)

Speaker Compensated XLR Balanced, 1/4" unbalaced

Effects Volume

Yes, 3 individual returns

Effects Loop / Location

Yes / Rear

Effects Footswitch / Function

Yes / Internal reverb and external effects globally defeatable

Internal Reverb / Effects

Accutronics® Spring Reverb

External Speaker Output / location

Yes / rear (Dual selectable Impedences)

Headphone Jack

Yes

Other Features

Standby Switch, Auto tube matching, DC filaments on preamp

tubes, Tuner mute, Separate tuner output, Footswitchable

Solo boost, Presence & Resonance

Dimensions (DWH, inches)

11.5 x 26.5 x 10.5

Dimensions (DWH, cm)

29.25 x 67.5 x 26.75

Weight (lbs / kg)

44 / 20

The formula to calculate Total Impedance for a parallel

system is …

1/RT = 1/R1 + 1/R2 + 1/R3 +1/R4 …

R = Rated Speaker Impedance

RT = Total Speaker Impedance

R1… = Speaker Impedance

Examples (Speaker cabinets connected in parallel)

One 4-ohm cabinet = 4-ohms

Two 4-ohm cabinets = 2-ohms

Four 4-ohm cabinets = Not Recommended

One 8-ohm cabinet = 8-ohms

Two 8-ohm cabinets = 4-ohms

Four 8-ohm cabinets = 2-ohms

One 16-ohm cabinet = 16-ohms

Two 16-ohm cabinets = 8-ohms

Four 16-ohm cabinets = 4-ohms

Eight 16-ohm cabinets = 2-ohms

Replacement Tube Selection & Bias**
The YCS100 comes from the factory equipped with

matched EL34EH output tubes. The circuitry has been

designed to accommodate any type of EL34/6CA7 as

well as any type of 6L6/5881 output tubes, as long

as the four output tubes be of a matching type. The

amplifier has also been equipped with bias sensing

points for each of the output tubes as well as a bias

adjustment pot that can all be accessed without

removing the chassis from the box. This makes tube

replacement quick and easy.

**We recommend adjusting the zero signal bias to +250

mV +/-30mV DC at each of the test points. Bias adjustment

should be done with the amplifier configuration in the 100

Watt mode. Please refer servicing to qualified personnel.

Advertising