Connections – Panasonic WV-CS954 Manuel d'utilisation

Page 18

Advertising
background image

Pin no.

Power source

1

2

3

4

24 V AC LIVE

24 V AC NEUTRAL

Ground

Not use

CONNECTIONS

-18-

Coaxial Cable (5C-2V)*2

24 V AC

24 V AC Cable for camera

RS485 Data Port

To VIDEO IN port
(CAMERA IN)

8P Alarm Cable (provided)

PP Alarm Cable (provided)

To sensor, etc.

To buzzer,
display device, etc.

To Matrix Switcher,
etc.

Video Output
Connector

Alarm Input
Connector

Alarm Output
Connector

Twisted Pair Cable*1

(BNC)

(RJ-12)

RS485 Data Port

Alarm Input Connector

Alarm Output Connector

T(B)
T(A)
R(B)
R(A)

Red

Orange

Yellow

Green

Data
Tx

Data
Rx

(RJ-12)

Alarm In 2 (Red)

Alarm In 1 (Black)
GND (Brown)

Alarm In 3 (Yellow)

Alarm In 4 (Blue)

GND (Orange)

GND (Light Blue or Green)

GND (Violet)

Alarm Out 2 (Pink)

Alarm Out 1 (Gray)
GND (White)

GND (Light Green
or Light Blue)

*1: For twisted pair cable, use shielded low-impedance cable with a thickness of at least AWG#22

(0.33 mm

2

).

*2: Keep the overall length of coaxial cable under 1200 meters (in the case of 5C-2V).
*3: Be sure to connect the grounding cable to ground.

Alarm In/Out Ratings
Alarm In

: 5 V DC pull-up input. Drive capacity of at

lease 0.2 mA required.
OFF : 4 V DC minimum 5 V DC maximum,

or open

ON : 1 V DC maximum or short

Alarm Out : Open collector output. 16 V DC, 100 mA

maximum drive capacity
OFF : Open
ON : 100 mA maximum

* When connecting to an external device, set up the

system so the ratings are not exceeded.

Note: Do not turn off camera power within 30 seconds
after turning it on. Doing so can cause pan, tilt, zoom,
or focus to go out of position.

Precautions

• The following connections should be made by qualified service personnel or system installers in accordance

with all local codes.

• See the reverse side of the cover page for main lead connection.

#24

(0.22mm

2

)

Copper wire size
(AWG)

Length
of cable
(approx.)

(m)

(ft)

#22

(0.33mm

2

)

#20

(0.52mm

2

)

#18

(0.83mm

2

)

20

30

45

75

65

100

160

260

• 24 V AC Power Supply Connection

Recommended wire gauge sizes for 24 V AC line

Accessory Connector Information

1

3

2

4

Advertising