Replacing the lithium battery, Troubleshooting – Panasonic UF-890 Manuel d'utilisation

Page 150

Advertising
background image

Troubleshooting

150

During the initial self test, when the power is turn “On”, the machine will evaluate the condition of the back
up battery. If the battery is weak or fully discharged, the following message will be shown on the display.

REPLACE BATTERY

INFO. CODE=026

NOTE

1. The service life of the battery is approximately 1 year when the machine is turned “Off”.

Replacing the Lithium Battery

To replace the battery, follow the procedure below:

1

(1) Turn the Power Switch to the “O” (OFF)

position.

(2) Open the ADF Door.

(3) Remove the Battery together with the

Battery Holder.

Caution: Dispose the Lithium battery

properly and keep it away from

small children.

2

Replace the Lithium Battery.

(Order No.: CR2032)

Caution: When replacing the battery make

sure to observe the polarity to
avoid damage to the machine.

3

(1) Install the Battery Holder into the machine.

(2) Close the ADF Door.

(3) Turn the Power Switch to the “I” (ON)

position.

4

If the clock is flashing on the LCD Display,

follow the procedure on page 26 to reset the

clock.

3

2

1

2

Advertising