Ceiling mount bracket safeguards – Panasonic PT-D4000U Manuel d'utilisation

Page 54

Advertising
background image

54

Ceiling Mount Bracket Safeguards

The projector and the ceiling mount bracket are designed sufficiently safety though, make sure the safety cable
provided with the projector is installed and attached to the bottom of the projector when mounting in the ceiling for
safety and security.

Installation work of the ceiling mount bracket should only be carried by a qualified technician according to the
following procedure.
• Even if it is guarantee period, the manufacturer is not responsible for any hazard or damage caused by using a

ceiling mount bracket which is not purchased from an authorized distributors, or environmental conditions.

• Make sure to use a torque driver and do not use an electrical screwdriver or an impact screwdriver.
• An unused ceiling mount bracket should be removed promptly by qualified technician.

The followings are included with the other accessories.

<Installation procedure>

Install the ceiling mount bracket
according to the Installation
Instructions.

Attach anchor nuts or curl plugs
available in the market (M8 or 5/16") to a
strong ceiling surface in positions (left
figure) so that there is no slack in the
wire cable provided with the projector.

Pass the loop of wire rope through
anchoring area and tighten the hex
head bolts.

Attach the metal fittings at the ends of
the cable to the locking holes in the
projector main unit using the provided
wire fastening M6 screws, and tighten
the screws firmly to secure the
projector.

;;;

max. 1 m (3'3")

(recommended)

Wire cable

Hex head bolt (M8 or 5/16")

Flat washer

Spring washer

Anchoring nuts
or curled plugs (M8 or 5/16")

max. 1 m (3'3")

(recommended)

* If for any reason the enclosed screw become lost or

misplaced, please use the following.
Screw diameter: M6, Length:10 mm (the effective
thread depth on the receiving side is 10 mm)

* Likewise if the screws for attaching the custom

ceiling mount bracket go missing, please use the
following.
Screw diameter: M6, Length:10 mm (the effective
thread depth on the receiving side is 10 mm)
Torque Loading: 4±0.5 Nm (for 6 mm screw)

Cabinet Exterior

Securing Screw
(M6)

Wire metal end fitting

Effective screw depth
10 mm

Safety cable [TTRA0146]

Wire fastening M6 (Length:10 mm)
screw (x 1)

Wire cable (x 1)

Advertising