INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Level

Drill

1

¹⁄₄" drill bit

³⁄₈" (8 mm) nut driver or ratchet

Pencil

Pliers

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Phillips screwdriver

Flat-blade screwdriver

Saber or keyhole saw

Vent clamps

Metal snips

Parts supplied

Check that all parts are included.

Literature package

2 screws

Damper

Plastic cover (used for customized front panel)

Hardware package

Parts needed

Two

¹⁄₂" (12.7 mm) UL listed or CSA approved conduit

connectors

Wall cap

Metal vent system

Power supply cable

Optional parts needed:

Wood filler strips for cabinets with recessed bottoms. Length
and thickness determined by recess dimensions. See
“Prepare Location” section.

Two, 1" x 1" x 5" (25.4 x 25.4 x 127 mm) wood pieces for
cabinet floor. See “Prepare Location” section.

Four, 1

¹⁄₄" (31.8 mm) wood screws

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating plate is located behind the left filter on the rear wall of
the vent hood.

Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.

Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your
cooktop/range manufacturer installation instructions before
making any cutouts.

Grounded electrical outlet is required. See “Electrical
Requirements” section.

The hood is factory set for vented installations through the
roof or wall.

For non-vented installations, Recirculation Kit Part
No. 883140 is available from your dealer or an authorized
parts distributor.

All openings in ceiling and wall where range hood will be
installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.