Warning, Connect the vent system – KITCHENAID 9763393A Manuel d'utilisation

Page 11

Advertising
background image

11

3. Connect the black wire of the power supply cable to the

black wire in the hood with a twist-on connector.

4. Connect the power supply ground wire to the green ground

screw inside the vent hood terminal box.

5. Replace the terminal box cover.

Connect the Vent System

Vented installations:

Replace the metal filter. Connect the vent system to the hood
vent opening. Seal the connection with clamps.

Recirculation installations:

Connect the vent system to the hood vent opening. Seal the
connection with clamps.

Install Recirculation Kit (Part Number 883140)

1. Pull out on the range hood to expose the filters.

2. Remove the 2 metal filters.

3. Locate tabs “A” and slots “B” in the opening. This is where

the filter will fit into place.

4. Place charcoal filter into opening, resting the back of the filter

on tabs “A,” then clip filter tabs “C” into slots “B.”

5. Replace metal filters.

6. Reconnect power.

7. Check the operation of the vent hood fan and light.

8. Push the range hood back in.

To order replacement kits, see the “Assistance or Service”
section.

A. White wires
B. Green ground screw

C. Ground wire

D. Black wires

E. Twist-on connectors

A. Filter

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green ground screw in
terminal box.

Failure to do so can result in death or electrical shock.

E

B

C

D

A

A

A. Tab
B. Slot

A. Tab
B. Slot

C. Filter tabs

A

B

A

B

A

C

Advertising