Connect range to downdraft system – Jenn-Air W10253462A Manuel d'utilisation

Page 20

Advertising
background image

20

Connect Range to Downdraft System

1. Attach flexible vent (provided) to the blower motor inlet using

a vent clamp.

2. Check countertop height to allow range top to clear

countertop. Adjusting leveling legs if necessary.

3. Remove access panel by grasping both sides, pulling

upward, and lifting out.

4. Move range close to cabinet opening.

5. Plug range into grounded outlet (if using a power supply

cord).

6. Plug range electrical connector into the downdraft blower

motor.

7. Remove cardboard or hardboard from under the range. Using

2 or more people, gently move range into its final location.

8. Check that the anti-tip bracket is installed and that electrical

cords are not kinked. Use a flashlight to look underneath the
bottom of the range.

Look for the anti-tip bracket securely attached to floor or
wall.

Slide range back so rear range foot is under anti-tip
bracket.

9. Level the range.

a.) Place rack in oven.

b.) Place level on rack and check levelness of the range, first

side to side; then front to back.

c.) If range is not level, pull range forward until rear leveling

leg is removed from the anti-tip bracket.

d.) Use a wrench or pliers to adjust leveling legs up or down

until range is level.

e.) Push range back into position.

f.) Check that rear leveling leg is engaged in anti-tip bracket.

NOTE: Range must be level for satisfactory baking performance.

A. Inlet flexible vent
B. Vent clamp

A. Power supply cord (on some installations)
B. Range electrical connector to blower motor

1

2

1

A

B

A

B

Advertising