John Deere HR1-20E Manuel d'utilisation

Page 18

Advertising
background image

8

Electric Air Compressor Manual

Defective inlet (reed) valve.

Replace.

Tighten connection.

Air blowing from air intake filter.

Pressure regulator not turned to

high enough pressure or defective.

Air leaks or restrictions.

Restricted air intake filter.

Hose or hose connections are too

small or long.

Air compressor is not large enough

for air requirement.

Restricted check valve.

Insufficient pressure at air tool or

accessory.

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY

Adjust pressure regulator to proper

setting or replace.

Check for leaks and repair.

Clean or replace air intake filter.

Replace with larger hose or

connectors.

Check the accessory air require-

ment. If it is higher than the

CFM or pressure supply of the air

compressor, you need a larger air

compressor.

Clean or replace.

Air leaks from safety relief valve.

Possible defective safety relief

valve.

Excessive air tank pressure.

Operate safety relief valve manual-

ly by pulling on ring. If it still leaks,

it should be replaced.

Defective pressure switch. Reset

or replace.

Air leaks at pump.

Defective gaskets.

Replace gaskets and torque head

bolts as stated in parts list.

Defective or incorrectly sized easy

start valve.

If air tank pressure gauge registers

over 40 PSI, easy start valve is

defective. Replace.

If air tank pressure gauge registers

under 40 PSI, your altitude may

require an easy start valve with a

lower PSI rating.

Air leaks from easy start valve.

Restricted air intake filter.

Defective (reed) valve.

Air compressor not making enough

air.

Clean or replace.

Drain air tank and measure pump

up time. Compare to specifications.

If lower, remove pump head and in-

spect valve plate, clean or replace.

Air continues to leak at pressure

switch bleed off while motor is run-

ning.

Defective pressure switch.

Air bleed off line is loose.

Replace.

Air continues to leak at pressure

switch bleed off while motor is

stopped.

Defective check valve.

Remove, clean or replace.

Advertising