Electric Air Compressor Manual

PRE-START CHECKLIST:

. Check oil level, add if necessary.

. Remove any moisture in the air compressor air tank.

NEVER attempt to

open the Air Tank Drain Valve when more than 10 PSI of air pressure is

in the air tank! Remove excessive pressure with an air tool, then open the

air tank drain valve in the bottom of the air tank. Close tightly when drained.

3. Make sure the pressure switch is in the "OFF" position.

4. Make sure the safety relief valve is working correctly.

5. Make sure all guards and covers are in place and securely mounted.

START-UP:

. Read safety warnings before performing operation.

. Ensure the pressure switch is in the "OFF" position.

3. Plug the power cord into a grounded outlet.

4. Move the switch on the pressure switch box to the "ON" position. This will

allow the air compressor to start building up pressure in the air tanks. You

will hear an air leak for the first 20-50 seconds until the easy start valve closes.

This will stop when correct pressure is achieved. When pressure drops with

usage, the air compressor will start automatically.

5. Set pressure by adjusting the pressure regulator knob counterclockwise for

less pressure and clockwise for more pressure.

6. If you notice any unusual noise or vibration, stop the air compressor and refer

to "Troubleshooting".

SHUTDOWN:

. To stop the air compressor, move the switch on the pressure switch box to

the "OFF" position. Never stop the air compressor by unplugging it from the

power source. This could result in risk of electrocution or damage to unit.

. Drain air from the air tanks by releasing air with an attached air tool or by pulling

on the Safety Relief Valve.

3. Once the Air Tank Pressure Gauge registers under 0 pounds, open the Air Tank

Drain Valve under each air tank to drain any moisture.

4. Allow the air compressor to cool down.

5. Wipe the air compressor clean and store in a safe, non-freezing area with the

cord coiled up and protected from accidental damage.

EXAMPLES OF POSSIBLE CORD PLUGS AND CORRESPONDING RECEPTACLE

WARNING

RISK OF BODILY INJURY!

Never attempt to open the air tank

drain valve when more than 0

PSI is in the air tank!

OPERATING INSTRUCTIONS

6-15R

6-15R

L15-30R

L15-30P

5-20P

5-20R

GROUNDED

OUTLET BOX

GROUNDED

OUTLET

6-50P

6-50R

W

W

G

G

G

G

G

G

Z

Z

Y

Y

G

G

X

X

125V

20A

(5-20)

250V

15A

(6-15)

250V

50A

(5-20)

3 250V

30A

(15-30)

(B)

(A)

(D)

(C)

(E)

GROUNDING

PIN