OUOD006,0000018

–19–16JUN04–3/4

TYB4762

–UN–07SEP04

TY25864 Control Panel

B—CHARGE RATE Button
C—BATTERY TYPE Button
D—CHARGING (yellow) LED

NOTE: Charger is set to default state of 2 amp (2A)

charge rate and 12V REGULAR battery type.

7. Press CHARGE RATE button (B) to select desired

charging amps as follows:

• 2 amp (2A)- for small batteries commonly used in

garden tractors, snow mobiles, and motorcycles. Not
for use as trickle charger or for larger batteries.

• 15A or 40A- for automotive, marine, and deep cycle

batteries. Not for industrial applications.

8. Press BATTERY TYPE button (C), if necessary, to

select battery type as follows:

NOTE: If battery type is unknown, select REGULAR

setting.

NOTE: Within a few seconds, charging process begins

and CHARGING (yellow) LED (D) illuminates.

If CHECK (red) LED illuminates, check for correct
cable connections.

• 12V REGULAR- used in cars, trucks, motorcycles,

and agricultural equipment. Batteries have vent caps,
and are often marked “low maintenance” or
“maintenance-free”.

• 12V DEEP CYCLE- often larger than other types.

Usually marked “deep cycle” or “marine”.

• 12V AGM, GEL- have sealed cases without vent

caps.

• 6V REGULAR- used in older cars and agricultural

equipment, and some specialized vehicles.

NOTE: If a battery is left discharged for an extended

period, it becomes sulfated and may not accept a
normal charge. The charger will sense this
condition and switch to a special desulfation mode
of operation, indicated by a blinking CHARGING
LED. If successful, normal charging will resume,
indicated by a continuously illuminated
CHARGING LED. This mode can take up to 10
hours.

9. Select BATTERY % mode to determine charging

progress after charging has begun.

10-9