John Deere TY25862 Manuel d'utilisation

Page 31

Advertising
background image

Controls and Operation

OURGP12,0000004

–19–09JUN04–3/3

TYB4742

–UN–31AUG04

TY25862 Control Panel

B—Charge Time Switch
C—Charge Rate Switch

CAUTION: NEVER charge a frozen battery.

IMPORTANT: Do not use battery charger to start

vehicle without a battery in it.

7. Turn charge time switch (B) from OFF to HOLD

position.

8. Set charge rate switch (C) to the Engine Start position

for the voltage of the vehicle being started.

IMPORTANT: Do NOT crank engine for more than 3

seconds at a time. Wait for at least 4
minutes between attempts to start
engine.

NOTE: In extremely cold weather, or when battery is

severely exhausted, charge battery for 5 minutes
before cranking engine.

9. Crank the engine for no more than 3 seconds.

10. If engine does not start: Wait 240 seconds (4

minutes) before attempting to start vehicle again.

NOTE: In extremely cold weather, or when battery is

severely exhausted, wait 240 seconds (4 minutes)
after cranking engine, then charge battery for 5
more minutes before attempting to start vehicle
again.

If engine starts:Turn charge rate switch to OFF

position, unplug AC power cord, disconnect clamp to
ground (chassis or engine block), then disconnect
clamp to battery terminal.

15-16

091604

PN=31

Advertising