ENGLISH

WARNINg: When using this unit, basic precautions should always be followed, including the following.
WARNINg: Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the

manufacturer.
DANgER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.
WARNINg: Never drop or insert any object into any opening.

INStALLAtION

NOtE: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation

according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the

installation of all Jacuzzi

©

Whirlpool Bath products. Our warranty does not cover improper installation related problems.

NOtE: Install this unit in accordance with the Canadian Electrical Code, Part 1.
CAUtION: This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use supply

wires that are suitable for 75°C, including the temperature rating of the supply conductors to be used.
This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber.
Building materials and wiring should be routed away from the motor/pump or blower or other heat producing components of this

unit.
A pressure wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG (8.4 mm)

solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to

comply with local requirements.
DANgER: Risk of electric shock. Connect only to a circuit protected by a ground fault circuit interruptor (GFCI).
WARNINg: This unit must be connected only to a supply circuit that is protected by a 15 A ground fault circuit interrupter (GFCI).

Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button.

The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner,

the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current flowing,

indicating a possibility of an electric shock. Do not use this hydromassage bathtub. Disconnect the hydromassage bathtub and

have the problem corrected by a qualified service representative before using.
WARNINg: (For permanently connected units) A green-colored terminal (or a wire connector) marked “G,” “GR,” “GROUND,”

or “GROUNDING”) is provided within the terminal compartment. To reduce the risk of electric shock, connect the terminal or

connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit

conductors supplying the equipment.
For built-in and drop-in units, install to permit access for servicing.