Jacuzzi

©

Whirlpool Bath: Installation and Operation

Page 10

BE76000F • December 2007

ENGLISH

INStALLAtION

FRAMINg AND SUPPORt

The optional drain/overflow of the bath extends below the bottom

of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to

support a total weight of bath, water, and bather. Refer to

the table under total weight for your model. The unit must

be supported from the bottom of the bath and not from the bath

rim or nailing flange. If the subfloor is level and a continuous

surface, no other preparation is necessary. You can proceed to

install the bath. If the subfloor is not level, you

MUSt level the

entire surface prior to installing the bath. The use of materials

that shim or provide a level installation are allowed provided

the method used will insure a level bath that is supported from

the bottom. Materials that may be used are a floor leveling

compound, mortar, plaster or minimal expansion structural

foam; however the bath must remain level in order for it to

drain properly and all foam feet must make full contact with

the leveling material. Both sides of a joint or splice of subfloor

should be level to each other.
The rim of the bath is not designed to support weight. If finish

material is to overlap or contact the bath, the added weight must

be fully self-supporting.
Install optional trim parts when all installation has been

completed.

ANChOR StRAP

Drop-In Bath units are equipped with metal anchor straps.

These straps can be used to secure the unit to the floor or sub-

floor to reduce movement after installation. If mortar or similar

anchoring material is used, these straps are not necessary.
WARNINg: ALL foam feet must contact the floor. Anchoring

straps and/or other anchoring materials will not properly anchor

unit if ALL foam feet are NoT in contact with a level floor.

Operating a unit improperly installed may cause irreparable

damage to the unit.

SERVICE ACCESS

For partially or fully sunken installations, allow for access

to service connections. It is the installer’s responsibility to

provide sufficient service access. The recommended minimum

dimensions allowable for service to the bath are shown in the

“Service Access” illustration below.
Provide adequate ventilation for cooling and to supply sufficient

air for the blower. Do not insulate this area or around blower or

motor.

tYPICAL INStALLAtION (Semi-Sunken)

Sealant

Mortar or adhesive

Tile

Flashing

Sub-floor

1 x 4 inch

(Not for support

Anchor strap

Floor

Nail or screw

through anchor

strap into floor

ANChOR StRAP

SERVICE ACCESS REQUIRED

FRONT

ALTERNATE

ACCESS

Blower

PREFERRED

ACCESS

18”

12”

18”

12”