45" (114.3 cm) Cooktop

*A minimum clearance of

6¹⁄₄" (15.9 cm) is recommended for

removal of the grease containers. Installed dimension for the
grease containers is 5

¹⁄₂" (14.0 cm).

**A minimum clearance of

2" (5.1 cm) is recommended between

the motor/blower and cabinet for proper cooling.

Cabinet Dimensions

A. Tie down bolt (on each side of cookop)
B. 45" (114.3 cm)

C. 21

³⁄₄" (55.3 cm)

D. Grease containers

E. Wiring box cover

F. Blower

A. 6

¹⁄₄" (15.9 cm)

B. 3

¹⁄₂" (8.9 cm)

C. Grease containers
D. 2" (5.1 cm)

E. 13

³⁄₄" (34.9 cm)

F. 26

³⁄₄" (68.0 cm)

G. 4" (10.2 cm)

H. 13

¹¹⁄₁₆" (35.1 cm)

A

F

E

D

B

C

A*

D**

C

B

E

F

G

H

C

A. 30" (76.2 cm) on 30" (76.2 cm) models

45" (114.3 cm) on 45" (114.3 cm) models

B. Combustible area above countertop (shown by dashed box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop platform

and bottom of uncovered wood or metal cabinet (24" [61 cm]
minimum clearance if bottom of wood or metal cabinet is covered
by not less than

¹⁄₄" [0.6 cm] flame retardant millboard covered with

not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth

E. 1

⁷⁄₈" (4.8 cm) min.

F. 21" (53.3 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop

within minimum horizontal clearances to cooktop

H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of

countertop

I. Junction box or outlet; 10" (25.4 cm) from right-hand side of

cabinet

J. 29

¹⁄₁₆" (73.9 cm) on 30" (76.2 cm) models

43

¹⁄₄" (109.9 cm) on 45" (114.3 cm) models

K. 2½" (6.4 cm) minimum distance to nearest left and right side

combustible surface above cooktop

L. 1½" (3.8 cm) minimum clearance between back wall and

countertop

D

A

E

I

J

K

G

H

L

C

F

B