Warning, Install cooktop, Make electrical connection – Jenn-Air W10298937A Manuel d'utilisation

Page 10

Advertising
background image

10

Install Cooktop

1. Using 2 or more people, place cooktop right side up into the

cutout.

NOTE: Make sure that the front edge of the cooktop is
parallel to the front edge of the countertop. If repositioning is
needed, lift entire cooktop up from the cutout to avoid
scratching the countertop.

2. Connect blower exhaust scroll to ducting.

3. Use vent clamps to secure the ducting to the blower exhaust

scroll.

4. Turn tie down bolts clockwise until they contact the bottom

side of the countertop, then tighten

¹⁄₄ turn more.

5. Install grease container(s) to bottom of cooktop.

6. Reinstall grease filter.

7. Reinstall vent grille.

Make Electrical Connection

This cooktop is manufactured with a white (neutral) power supply
wire twisted together with a green (or bare) grounding wire
connected to the cooktop.

Home power supply cable and connectors are not provided.

See the “Electrical Connection Options” chart to complete
installation for your type of electrical connection.

Electrical Connection Options

4-Wire Cable from Home Power Supply to 4-Wire Cable
to Cooktop

IMPORTANT: Use the 4-wire cable from home power supply in
the U.S. where local codes do not allow grounding through
neutral, New Branch circuit installations (1996 NEC), mobile
homes and recreational vehicles, new construction, and in
Canada.

1. Disconnect power.

2. Remove wiring box cover from the cooktop plenum.

3. Remove the appropriate knockout for the size of the home

power supply cable on the bottom side of the cooktop wiring
box. Use a UL listed or CSA approved strain relief to connect
home power supply cable to cooktop wiring box.

4. Connect the green (or bare) ground wire from the home

power supply to the green (or bare) ground wire in the plenum
wiring box using the UL listed wire connectors.

5. Connect the 2 black wires together using the UL listed wire

connectors.

6. Connect the 2 red wires together using the UL listed wire

connectors.

7. Connect the 2 white wires together the UL listed wire

connectors.

8. Tighten screws on the strain relief.

9. Install cooktop wiring box cover on plenum wiring box.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death,
fire, or electrical shock.

If your home has:

And you will be
connecting to:

Go to Section:

4-wire

A fused
disconnect or
circuit breaker
box

4-Wire Cable from
Power Supply

3-wire

A fused
disconnect or
circuit breaker
box

3-Wire Cable from
Power Supply

A. Green (or bare) ground wires
B. White wires

C. Black wires
D. Cable from home power supply

E. Plenum wiring box

F. Red wires

G. UL listed wire connector

H. UL listed or CSA approved

strain relief

½"

(1.3 cm)

½"

(1.3 cm)

A

B

C

F

D

E

G

H