Installation requirements, Tools and parts, Location requirements – Jenn-Air W10298937A Manuel d'utilisation

Page 2

Advertising
background image

2

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Parts supplied

Vent grille

Grease filter

Grill cartridge

Grease container(s)

Hold-down straps (4)

Clamping screws (4)

Parts needed

A UL listed or CSA approved strain relief for

⁷⁄₈" (2.2 cm)

knockout.

A UL listed or CSA approved conduit connector for

¹⁄₂" (1.3 cm) trade-size metal-clad conduit

UL listed wire connectors

Metal ducting

Jenn-Air wall cap

Jenn-Air

®

6" (15.2 cm) Round Surface Wall Cap Damper

Order Part Number A406

Jenn-Air

®

3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper

Order Part Number A403

To order, see the “Assistance or Service” section of the Use
and Care Guide.

Vent clamps

Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.

It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.

To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.

Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.

Grounded electrical supply is required. See “Electrical
Requirements” section.

If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.

IMPORTANT: An under-counter built-in oven cannot be installed
under this product.

Product Dimensions

30" (76.2 cm) Cooktop

*A minimum clearance of

6¹⁄₄" (15.9 cm) is recommended for

removal of the grease containers. Installed dimension for the
grease containers is 5

¹⁄₂" (14.0 cm).

**A minimum clearance of

2" (5.1 cm) is recommended between

the motor/blower and cabinet for proper cooling.

Tape measure

Flat-blade screwdriver

Phillips head screwdriver

Drill

Level

6" socket extension

Marker or pencil

Pliers

¼" drill bit

Jigsaw

Ratchet with

³⁄₈" socket

A. Tie down bolt (on each side of cookop)
B. 30" (76.2 cm)

C. 21

³⁄₄" (55.3 cm)

D. Grease containers

E. Wiring box cover
F. Blower

A. 6

¹⁄₄" (15.9 cm)

B. 3

¹⁄₂" (8.9 cm)

C. Grease containers
D. 2" (5.1 cm)

E. 13

³⁄₄" (34.9 cm)

F. 11

¹³⁄₁₆" (30.0 cm)

G. 4" (10.2 cm)

H. 13

¹³⁄₁₆" (35.1 cm)

B

C

A

F

E

D

A*

B

D**

E

F

G

H

C

C

Advertising